E-Series magnetic flowmeters are unaffected by moisture. The transmitter is designed with dual compartments and uses local operator interface technology to keep the electronics moisture-free and maintain safe local configuration in hazardous environments. The sensor is all-welded to eliminate gaskets and prevent moisture ingress.
Learn MoreCatalogue; Download Area. Catalogue. Flovac catalogue. Medical Line - catalogues. Declarations of Conformity - Medical Line. Catalogue. Quality Certificates and CE Certificates - Medical Line.
Learn MoreOpen the catalog to page 1 Reinach, Switzerland Cernay, France Greenwood, US A > Open the catalog to page 2 Flow is the process variable most frequently measured in industry. Water, natural gas, steam, mineral oil, chemicals or wastewater are only some examples of uids that have to be measured day in, day out. Check it out!
Learn MoreMultiple Flow Meter Options - The System-10 may be ordered with any of ONICON's inline, insertion, or clamp-on style flow meters. This ensures the best metering technology can be chosen for all application and installations. Multiple Temperature Sensor Options - The System-10 may be ordered with a pair of matched ONICON's
Learn MoreType 303 and 316 stainless steel flow meters have a 6,000 psi (414 bar) maximum operating pressure in ¼ and ½ inch models and 5,000 psi (345 bar) maximum operating pressure in ¾ to 1½ inch models. All liquid flow meters are designed with a 3:1 safety factor. High temperature affects maximum operating pressure.
Learn MoreSierra’s flow meter catalog not only allows you to select products by gas, liquid or steam, but it gives you the option to search by technology: thermal, vortex or ultrasonic. Get detailed
Learn MoreHydraulic Diagnostic Products. Flo-tech is a leading brand of portable testers and turbines for hydraulic fluids with enhanced operational features and their rugged dependability. Flo -tech products are manufactured by internationally renowned Badger Meters. Measuring water, oil, chemicals, and other fluids, Badger Meter products are known for
Learn MoreVersaFlow Clamp-on Ultrasonic. Flowmeter stands for continuity and long-term reliability. Flow measurement can be done anywhere and startup is immediate. The
Learn MoreThe instruction manual concerns the installation, operation, checkup and maintenance of the Flow transmitter (FLR) and. Detector (FLS) of ultrasonic flowmeter.
Learn Moreof the meter, which is designed to stop the flow of liquid whenever air is present to ensure accurate measurement. K‐80 Check Valve V‐50‐LPG Differential Valve Technical Specification
Learn MoreThis manual contains detailed operating instructions for the. FUSION flow meter. The following condensed instructions are provided to assist an experienced
Learn Moreflow meter simplifies installation with NPT threaded process connections which match existing threaded pipe unions. The Rosemount 8800 Weld-End Vortex flow meter is directly welded into your process piping, eliminating flange gaskets. This is the only Vortex flow meter available with zero potential leak points. The Rosemount 8600 Utility Vortex
Learn MoreFlowmeter Catalog. 2016. Page 2. QSE Mag Electromagnetic Flowmeters .. 3 electromagnetic flowmeter designed for flow and usage.
Learn MoreMedium Capacity Chemical Flow Meters 12 Strainers & Air Eliminators / ”Y” Type Strainers 13 Model Designation - Flomec Oval Gear Mechanical Meters 14 Model Designation - Flomec Oval
Learn MoreElectromagnetic Flowmeter Open the catalog to page 2 Electromagnetic Flowmeter 1. Operating Principle The electromagnetic flow meter is an instrument for measuring the flow of conductive fluid using Faraday's electromagnetic induction law, and consequently the fluid must be electrically conductive.
Learn MoreUnrivalled in its breadth and scope, ABB flowmeters provide high-quality 1962 First wedge type flow meter for slurry service.
Learn MoreThe flow rate is the most basic measurement in a process. A variety of methods of measuring the flow rate Meter body: SUS316, SUS316L Case: aluminum alloy Fluid temperature -40 to +110°C Ambient temperature -25 to +60°C Output 4 to 20 mAdc Contact output: open collector Applicable fluids Gas, steam, liquid
Learn Morethe meter. Bluetooth® Connectivity Optional Bluetooth® interface enables wireless access to real-time data for fast commissioning and advanced diagnositcs. CALIBRATION All F-1000 Series flow meters are wet calibrated in a flow laboratory against standards that are directly traceable to National Institute of Standards and Technology (N.I.S.T.).
Learn MoreFlow adjustment valve max. 16 bar 1l/h 110 l/h 16 l/h 1600 l/h 4% 12 RGC1 Polypropylene Glass Flow adjustment valve max. 80ºC 25 ml/h 63 l/h 1,9 l/h 2400 l/h 2.5% 16 Glass 1/ 4 " Rp Easy tube replacement design max. 16 bar 25 ml/h 63 l/h 1,9 l/h 2400 l/h 2.5% 18 RGC2 Stainless Steel with flow adjustment valve Glass
Learn MoreFlowmeter Selection Guide. The standard product index below shows the flow measurement ranges in litres/min for air and water at standard operating
Learn MoreLCD display (max loading 100mA 30VDC, internalInstantaneous flow display scope:0~50000 Total flow display scope: 0~99999999 Protection grade IP65 Explosion-proof grade Exia II CT5Ga Exd II BT6Gb Products Catalog for Flow Meter . Electromagnetic flowmeter DN10~DN1200 Lining: Material of electrode: Medium: Grade of accuracy: Flow velocity: ≤ 15m/s
Learn MoreThe sturdy construction of this turbine flow meter means high performance and longer service life at an affordable price. Industry Standard The TRG Series flow meter comes with a standard NPT end connection for universal applications. Versatile This meter is capable of measuring flow in line sizes from 1/2" to 2". Electronic Integration
Learn MoreThe ideal flowmeter for each fluid Liquid applications • Liquids in general (e.g. water) • Very low flow rates (< 2 l/h) • Very high flow rates (> 100 000 m3/h) • Non-conductive liquids • Viscous liquids (> 50 cP)
Learn MoreClamp-on Detector & Portable Transmitter. Flow Using the flow transmitter FSC in combination with the Instruction manual / default language setting.
Learn Moreapplicationthe "dim" meter is designed for agriculturecontrol applications.the turbine is located at the top of the pipe.major section of the pipe is free for water flow.features•one measuring unit for all meter sizes•magnetic drive•low head loss•optional electrical output•hermetical vacuum-sealed register•easy reading, by a 360¢ª rotating
Learn MoreThe measurement principle of electromagnetic flowmeters. (EMF) is based on Faraday's law of induction. EMF can accurately measure the flow of any electrically.
Learn MoreTHERML MSS FLOW METER Allow enough slack in the flexible conduit to permit the meter to be removed from the valve. Installation kit for steel pipe (Dry tap or hot tap): Compression fitting 1" Full port ball valve 1" Close nipple 1" Weld-on branch outlet Minimum hole size = ⅞" Must be centered. ¾" FNPT conduit connection
Learn MoreIntegral Orifice Meter Run Assembly MINCO (INDIA) FLOW ELEMENTS PVT. LTD. Integral Flow Orifice Assembly is used when Differential The assembly consists of a orifice plate between two integral Pressure Transmitter has to be directly mounted on the orifice blocks having corner taps. Generally meter run pipe is assembly.
Learn MoreM7 1” PULSE FLOW METERS SUITABLE FOR FLOW RANGE 0.8-21 GPM 50 M10 1 NOTE: This catalogue is intended to provide general guidance on Macnaught's Positive Displacement Flow Meters. In order to select the most appropriate meter for your needs, please seek expert advice which is available free-of-charge from Macnaught's Technical Support Team
Learn MoreAll UNIVERSAL FLOW MONITORS catalogs and technical brochures FLOMEC® QSE 2 Pages TM SERIES 2 Pages G2 SERIES 2 Pages Piston Inline PI 6 Pages FS series 4 Pages FP series 4 Pages FD series 4 Pages SX general with X transmitter 6 Pages XHF gen with X trans (500 - 1500 GPM) 2 Pages MN general with X transmitter 6 Pages SN general with X transmitter
Learn Moremeter. Therefore, the frequency of vortex shedding is proportional to the volume flow. Operating Conditions Application : Gas, Liquid Steam Meter size : DN 15 to DN300 Flow : Liquid 1.2 – 6.2 to 200 - 2000 m3/h, Gas/Steam 5 – 25 to 1380 - 11000 m3/h Ambient Temperature : - 20 to +70 deg C. Fluid Temperature : - 20 to +350 deg C.
Learn More
Leave A Reply