30/07/ · This article focuses on products UL certifies for protecting membrane penetrations in these walls. Code Requirements. Section 712.3.2 of the 2006 International Building Code requires membrane penetrations of fire-resistance rated assemblies by recessed fixtures to be protected so that the required fire resistance is not reduced.
Learn MoreShaftwall. One layer 1″ x 24″ (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panel inserted between 2-1/2″ floor and ceiling runners of 2-1/2″ steel C-T, C-H studs. Opposite side:
Learn MoreDensGlass Shaftliner is listed as mold resistant in UL Environment's Sustainable In addition, DensGlass® Shaftliner shaftwall/stairwell assemblies.
Learn MoreThese assemblies are commonly used for single-family homes within five feet of a property line. UL Design No. V340 (1-hour from either side) UL Design No. U348 with stucco (both 1-hour from either side) UL Design No. U348 with brick (both 1-hour from either side) Benefits: No exterior gypsum is required.
Learn MoreSteel Studs — (Not shown)-"E" -shaped studs installed in place of "C-H" -shaped studs (Item 2) to secure the closure liner panels at the ends of
Learn MoreUL is a global independent safety science company. UL 263. ASTM. E119. Standards Used to Evaluate Assemblies Yes, this is a shaft wall.
Learn MoreUL UL U415 System E — Shaft Wall, Steel Stud (Non-Load-Bearing) Products Products > Pipe Insulation. Batts. Pipe and Tank . Blown-in Insulation. Board. Rolls. Elevated Temperature . UL Assemblies / Wall / UL U415 System E . UL U415 System E Shaft Wall, Steel Stud (Non-Load-Bearing) Stc 0; Fire Rating 2 Hour; System Thickness 3-3/4"
Learn MoreWall Assemblies USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and
Learn MoreThe UL Certification Mark on exterior wall assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements and is a key differentiator for products within the exterior wall assembly market. The UL Evaluation Report, an additional differentiator, provides
Learn Moreof wall differ between UL Design U373 and WHI GP/WA 120-03. Consult each listing for specific information. Approved for Assembly: DensGlass® Shaftliner
Learn MoreRoof-Ceiling Assemblies; Design Details; Shaft Wall Limiting Heights & Spans; Competitor Comparison Tool; USG Sustainability Tool; UL Type Designations; Frequently Asked Questions; Wall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details;
Learn MoreFully tested and approved assemblies for shaftwall construction. Provides maximum flexibility to choose from a variety of board manufacturers. Found in:.
Learn MoreOur testing services assess compliance to UL Solutions and industry standards, including: UL 263/ASTM E119 & BS476 Fire Resistance Rating. Smoke Leakage Testing. Our advisory services help ensure building owners that exterior wall assemblies will perform as expected and include: Building Envelope Forensic Services.
Learn MoreA 2-hour fire-resistive, non-load bearing non-combustible partition designed to enclose shaftwalls, containing elevators, ducts, piping, air shafts and similar construction applications. System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T studs and faced on one side with two layers of 1/2" Type C or 5/8" Type X gypsum board.
Learn MoreI need a UL fire rated assembly (walls and interior partitions, shaftwall head-of-wall, floor-ceiling systems, etc.), which assembly should I use?
Learn MoreAssembly Details. Gypsum Board. 1" thick Gypsum Liner Panel (UL Type SLX). Steel Studs. 4" CH Studs, 20ga. MSG., Spaced 24" O.C.. Insulation.
Learn MoreThe I-Stud Cavity Shaftwall System for Horizontal Duct Protection consists of I- Studs 24" o.c. with 1" Fire- Shield Shaftliner panels inserted in the stud tabs, and three layers of 1/2" Fire-Shield C Gypsum Wallboard attached to the stud flanges opposite the Shaftliner panels.
Learn More4. 1" thick Sheetrock® Brand Gypsum Liner Panel- UL Type SLX Friction-fitted in "H" portion of C-H studs. 5. Horizontal Stud Wall Assembly - The wall width is limited to the length of the Gypsum Liner Panel. 6. For more details and construction methods, refer to UL Design #U437 and the USGinstallation instructions. Page 5 of 11 1.
Learn MoreSeveral options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC Table 721.1 (2), Item 14-1.3 UL U332 1-Hour Double Wall UL U341 2-Hour Single wall UL U301 UL U334 IBC Table 721.1 (2) Item Number 14-1.5
Learn MoreBelow please find STC rated wall assemblies based on our acoustic lab tests and INSUL models. Lab tests are performed at NVLAP-certified laboratories in accordance with ASTM E90 and ASTM E492. If you don’t see the STC Rated Wall Assembly you need below, contact one of our acoustical engineers with the desired Assembly and Target STC Rating.
Learn MoreSHAFT WALLS. GA FILE NO. WP 7008. GYPSUM WALLBOARD, STEEL C-H STUDS. One layer 1" x 24" proprietary type X gypsum panels inserted between 2 1/2" floor and.
Learn More3-HR U-415 shaft wall UL Assembly. UL assembly, U-415. Reply. 0. Share. 1 Reply. Jessica Strks. 9 Months ago. Hilti Verified. EJ FAQ US 10.23 (002).pdf (724.85 KB) WL3278e.pdf Please advise if there is a UL assembly where the gap can be sealed and provide a
Learn MoreFind resources and details for UL rated wall systems with the required STC and fire ratings for your project. Products Products > Pipe Insulation. Batts. Pipe and Tank . Blown-in Insulation.
Learn MoreUL Listed Shaft Wall Assemblies, Ratings, Design Considerations. and Comparisons. UL listed U and V-series shaft wall – Static designs.
Learn MoreNational Gypsum pioneered the development of fire-rated horizontal membranes with UL design G586. This 2-hour horizontal shaftwall assembly
Learn MoreUL Design. Head of Wall Firestop System. Page. Detail No. Title. SW Series - Shaftwall Assemblies 09 21 16.23. SW 101. 1 Hour Shaftwall Partition.
Learn MoreUL U336. Area Separation Wall - Wood Stud (Non-Load-Bearing) Fire Rating. 2 hours. System STC. 66. System Thickness. 11.5 in. CAD/Revit & Acoustics.
Learn MoreMedium Voltage Power Conversion Equipment. UL Standard. Scope. Summary of Topics. Standard 347A, Edition 2 Edition Date: January 05, ANSI Approved: April 05, 2022 USD $402.00-$998.00. Purchase Options Get Update Alerts.
Learn MorezOnly products which bear UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U417 September 15, Nonbearing Wall Ratings — 1, 2 or 3 Hr BXUV.U417 Fire Resistance Ratings - ANSI/UL 263 Page Bottom
Learn MoreIt provides you with a choice and peace of mind knowing you’re using a tested and approved assembly. Shaftwall System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T
Learn Morenexrep jobs indeed; lilith in partners 8th house synastry
Learn More
Leave A Reply