Aluminum Burn Clip (AB) | ClarkDietrich Building Systems

The clips are used to hold the area separation wall assembly in place at the floor, roof and truss line between adjacent units. Should a fire break out in one unit, the Aluminum Burn Clips on the fire-ridden side of the area-separation wall will melt, allowing the wall structure for that side to collapse.

Learn More

Ul u347 wall assembly

8/19 · The assemblies listed below are a small sample of the UL Designs in which USG shaft wall systems can be used. For more details on fi re-rated assemblies, see USG literature SA926, Shaft Wall Systems. SSA926S_08.indd 3A926S_08.indd 3 99/13/07 1:33:52

Learn More

What You Should Know About Cavity Shaftwalls - National Gypsum

11/1 · How can I achieve a higher STC shaft assembly? Insulate the wall, use resilient channels or sound isolation clips, and/or install Gold Bond® BRAND SoundBreak® XP® as one of the face layers. Here are a few UL 2-hour rated designs that achieve an STC of 50 or higher: U497, STC 52 (Sound Test: NGC2017007), U498, STC 53 (Sound Test: NGC2015036).

Learn More

USG SHAFT WALL SYSTEMS - BuildSite

ASSEMBLY USG Shaft Wall Systems | 4 APPLICATIONS Use USG Shaft Wall Systems to construct elevator shafts, mechanical shaf ts, stairwells, air return shafts and horizontal membranes.

Learn More

USG Head of Shaft Wall Details Fire Resistant Assemblies - J2131

OF SUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGN PROFESSIONAL. 0 10/16/ 1 OF 1 01 HEAD OF WALL PARTITION DETAILS FIRE RESISTANT ASSEMBLIES HEAD

Learn More

H-Stud 18 mil | USG Shaftwall/Area Separation Walls | CEMCO

H-Stud – 18 Mil members slide over and engage edges of adjacent liner panels for solid area separation walls. The members are fabricated from hot-dipped galvanized steel complying with ASTM A653, with a minimum G40 coating. The framing members comply with ASTM C645. Fire and sound rated assemblies listed under the code and Gypsum Association

Learn More

USG CH Shaftwall Stud 34 mil - CEMCO

USG CH Shaftwall Stud 34 mil "CH" studs are fabricated in web depths of 2-1/2″, 4″, and 6″ each with a short-flange width of 1-3/8″ and long-flange width of 1-1/2″. All C-H studs manufactured by CEMCO are produced from hot-dipped galvanized steel in standard G40 coating. G60 is available upon special request.

Learn More

SECTION 092116.23 - GYPSUM BOARD SHAFT WALL

Product Data: For each component of gypsum board shaft wall assembly. B. LEED Submittals: USG Corporation; Sheetrock Brand Gypsum Liner Panel.

Learn More

USG Head of Shaft Wall Details Fire Resistant Assemblies

STEEL BEAM WITH FIREPROOFING REFERENCE STRUCTURAL DRAWINGS. FOR BEAM SIZE AND FIREPROOFING THICKNESS. USG SHEETROCK © BRAND SHAFT LINER GYPSUM PANELS, CUT TOP 

Learn More

Cavity Shaft Wall System - USG

USG Cavity Shaft Wall can be used in elevator and mechanical shafts, air ducts, stairwells, and areas where wall construction is only available from one side.

Learn More

Horizontal Shaft Assembly

APPLICATIONS Use USG Shaft Wall Systems to construct elevator shafts, mechanical shaf ts, stairwells, air return shafts and horizontal membranes.

Learn More

PDF Shaft Wall - CEMCOPDF

4 USG Shaft Wall Systems Overview USG shaft wall systems are non-loadbearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components

Learn More

AER-09038 - CEMCO

Two-Hour Horizontal Stud Shaft Wall Assembly (Non-Load Bearing), See Figure 6 1. A minimum 4" deep 20 gauge J-runner to be installed vertically, on the ends of the wall. 4. 1" thick Sheetrock®

Learn More

Shaftwall Systems - Bailey Metal Products

Shaftwall systems are nonload-bearing fire rated wall assemblies that provide The CH System is produced under license and control of USG Corporation.

Learn More

Cavity Shaft Wall - USG

The Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, stairwells and other

Learn More

PDF E:NER-258SW 2HrCorridorCeilingAndStairSoffit NER-258 SYSTEM G (1) - USGPDF

Title: E:NER-258SW_2HrCorridorCeilingAndStairSoffit NER-258 SYSTEM G (1) Author: EWatanabe Created Date: 9/5/ 9:55:15 AM

Learn More

Ul u529 shaft wall - zsi.szaffer.pl

A 2-hour fire-resistive, non-load bearing non-combustible partition designed to enclose shaftwalls, containing elevators, ducts, piping, air shafts and similar construction applications. System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T studs and faced on one side with two layers of 1/2" Type C or 5/8" Type X gypsum board.

Learn More

GYPSUM BOARD SHAFT WALL ASSEMBLIES - CertainTeed

Product Data: For each component of gypsum board shaft wall assembly. USG Corporation. . Retain "Manufacturers" Subparagraph 

Learn More

usg sheetrock® brand gypsum liner panels - Macopa

USG SHEETROCK® BRAND. GYPSUM LINER PANELS. 1 in. (25.4 mm) Type X gypsum liner panels with moisture resistance for use in shaft wall and area.

Learn More

Gypsum Board Shaft Wall Systems. CSI 3-Part Specifications

United States Gypsum Company USG, Gypsum Board Shaft Wall Systems. CSI 3-Part Specifications., identical with those of applicable assemblies tested per.

Learn More

XLSX USG Shaft and Stair Wall Systems.xlsx - doczz.netXLSX

A minimum 2-1/2" deep USG C-H studs 25 gauge, spaced 24" o.c., with the H-Section of the C-H stud towards the shaft side of the assembly. Screw attachment is not required to affix the stud to the runner, if Shaft Wall is less then 16 ft. tall. E-shaped studs may be used for closure panels at the end of walls or columns.

Learn More

PDF Cgc Shaft Wall Systems - UsgPDF

CGC Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.

Learn More

STC Rated Wall Assemblies - Lab Tested & INSUL Wall Assemblies

Below please find STC rated wall assemblies based on our acoustic lab tests and INSUL models. Lab tests are performed at NVLAP-certified laboratories in accordance with ASTM E90 and ASTM E492. If you don’t see the STC Rated Wall Assembly you need below, contact one of our acoustical engineers with the desired Assembly and Target STC Rating.

Learn More

Building Product: USG Shaft Wall System [10313b8] | ARCAT

USG Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.

Learn More

USG Middle East - Ceiling Systems and Drywall Assemblies

USG Middle East’s ever-growing portfolio of groundbreaking ceilings systems, drywall assemblies, and end-to-end solutions is backed by unparalleled quality service. With an extensive distribution and sales network operating for more than 25 years across the MENA Region, our dedicated teams provide local expertise and high levels of support in finding the right solutions for your

Learn More

Ul wall assemblies pdf - pav.floranet.pl

WALL ASSEMBLY GUIDE NFPA 285 Per Chapter 26 of the International Building Code, the wall assembly shall be tested in accordance with and comply with the acceptance The window opening perimeters shall be per UL Design Listings EWS0013, EWS0029, or EWS0054, as applicable. Title: CSFI-12630 NFPA 285 Exterior and Cavity Wall Assembly Guide.

Learn More

PDF USG Head of Shaft Wall Details Fire Resistant Assemblies - J2131PDF

USG SHEETROCK ©BRAND SHAFT LINER GYPSUM PANELS, CUT TOP OF PANEL 1" LESS THAN FLOOR TO CEILING HEIGHT, TYPICAL Scale: 3" = 1' - 0" HEAD OF WALL UL HW-D-0611 (1 AND 2 HOUR) 7 USG SHEETROCK © BRAND FIRECODE CORE GYPSUM PANELS, CUT

Learn More

How to install a ShaftWall system | British Gypsum

5/17 · ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system pro

Learn More

Assembly Detail - UL U415 UL System A - USG

UL U415 UL System A. Shaft Wall - Steel Stud (Non-Load-Bearing) Fire Rating. 1 hours. System STC. 39. System Thickness. 4.625 in. CAD/Revit & Acoustics.

Learn More

UL Wall Assemblies, Fire Rated Wall Designs | USG

Wall Assemblies USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and