hp5 rodinal 1+50

charte de développement noir&blanc | résultats Ilford HP5

film révélateur ISO dilution temps température Ilford HP5+ Agfa Rodinal 200 1+50 9m30 20° détails Ilford HP5+ Agfa Rodinal 400 1+25 7m30 20° détails Ilford HP5+ Agfa Rodinal 400 1+50 9m30 20° détails

Learn More

Dev it! - Ilford HP5+@800 in Rodinal / Adonal 1+50

Same brand. 2238 DELTA 100 DELTA 3200 DELTA 400 FP4+ High-Speed Infrared Film / HIE HP5 HP5+ Ortho Plus 80 P4 400. Same sensibility

Learn More

Tmax Vs Tri X Vs Hp5

D76 mixed 1+3 or HC100 mixed 1+50 and used one shot is not a world apart from Rodinal 1+50. 12 hours ago · Kata kunci ini. 2020-1-31 · This yielded nice, 

Learn More

Rodinal and HP5 plus: whats a good mix?

Jan 07,  · The Agfa USA data suggests an EI of 320 for HP5+ used in this way. Neither recommend 1+50, though the USA datasheet suggests that 1+100 for 20 mins will give an EI of 160 & a contrast index of 0.5 (Rodinal at 1+100 effectively ceases to do anything useful after 20 mins of developing I recall). However, Ilford's HP5+ datasheet states that the

Learn More

HP5+ and Rodinal - Film Forum

I have ben experimenting with Rodinal and Ilford HP5 +. If you used a normal 1+25 or 1+50 concentration and a normal development regime 

Learn More

Rodinal developer - uwsej.usinedematelas.fr

Appreciating Rodinal : The oldest commercial developer Gundlach Korona 5x7 with 4x5 back, Graphex Optar 135mm/4 I will If we e.g. look at the development times for HP5+ in Rodinal 1+50 for different exposures, you find the following numbers: 7 minutes @25ASA. 9 minutes @100ASA. 10-13 minutes @200ASA.. "/>

Learn More

FilmDev | Recipe Finder

Ilford HP5+ 400 in Agfa Rodinal 1+50 8 minutes astroturtle Ilford HP5+ 400 at 800 in Agfa Rodinal 1+50 16 minutes toesdelaloes Ilford HP5+ 400 at 800 in Agfa Rodinal 1/50 8 minutes

Learn More

Dev it! - Ilford HP5+@400 in Rodinal / Adonal 1+50

HP5+@400 in Rodinal / Adonal 1+50 11' FILM Ilford HP5+ FILM SIZE 120/220 EXPOSURE INDEX 400 DEVELOPER Rodinal / Adonal DILUTION 1+50 TEMPERATURE (° C) 20

Learn More

How many minutes should I develop Ilford HP5 in Rodinal 1:100?

Mar 08,  · Ilford HP5+ Rodinal 1+100 400 - 80. Share. Improve this answer. Follow answered Mar 8, at 20:34. Alaska Man Alaska Man. 3,521 9 9 silver badges 17 17 bronze badges. 1. OP is running stand dev, MDC is wrong. The developing difference between 80min and 120min is negligent because the developer will be exhausted in 60min. How many minutes

Learn More

HP5 in Rodinal | B&W film / developer combinations - Flickr

HP5+ developed in Rodinal 1+50 for 11 minutes at 19.5 degrees C. Agitation: one or two turns every (second) minute. A photo. A crop of the photo 

Learn More

Rodinal testing - 1:25 dilution - SidewaysEye

Scan from print: HP5 Rodinal 1:50. As you would expect the print from Rodinal 1:25 has more contrast as there is less compensation, 

Learn More

Rodinal and HP5 plus: whats a good mix?

1:50 or 1:25 -- those are the ratios to focus on if you're going to try out Rodinal. 1 part developer to 50 or 25 parts water10ml Rodinal and 

Learn More

Canon AE1 Ilford HP5 400 Rodinal 1+50, 11 min - Instagram

44 Likes, 1 Comments - Esther✌ (@fullcirclegrain) on Instagram: “ Canon AE1 Ilford HP5 400 Rodinal 1+50, 11 min”

Learn More

Ilford HP5+@400 in Rodinal / Adonal 1+50 - Dev it!

1. by nucifora; 2022-08-21 03:02:51; 0 Comments. HP5+@400 in Rodinal / Adonal 1+50. 11'. FILM. Ilford HP5+. FILM SIZE. 35mm. EXPOSURE INDEX 

Learn More

HP5 @ 6400 / RODINAL.1:50 : analog - reddit

HP5 @ 6400 / RODINAL.1:50. Close. Vote. Posted by 5 minutes ago. HP5 @ 6400 / RODINAL.1:50. 1 comment. share. save. hide. report. 100% Upvoted. Log in or sign up to leave a comment. Log In Sign Up. Sort by: best. level 1. Op · 4m. This is my test of pushing Hp5 to it's limits with my Nikon F3 and the 50mm 1.4. I've developed the film using the

Learn More

Ilford HP5+ 400 at 1600 in Agfa Rodinal 1:50 - Pinterest

Ilford HP5 Plus 400 pushed to 1600 and developed in Fomadon R09 NEW (basically Rodinal) 1+50, 25 min, 20°C. Visit. Save. More like this.

Learn More

Overexposed HP5 | Photo.net Photography Forums

If it is HP5, then that's a 3 stop overexposure. For Rodinal, I'd use a 1+50 dilution for 7-8 minutes (agitating once/minute), or 1+100 for about 20 minutes (agitating once every 2 minutes), to keep the highlights from blowing, and keep a good tonal range titrisol, Nov 18, 2005 #1 stefanjozef Sorry.it's HP5 Stefan stefanjozef, Nov 18, 2005 #1

Learn More

Film Developing Times ▸ Ilford HP5 in Rodinal - Digitaltruth

Film Developer Dilution ASA/ISO 35mm 120 Sheet Temp Notes; Ilford HP5+ Rodinal: 1+50: 25: 7: 7: 7: 20C: Ilford HP5+ Rodinal: 1+25: 100: 6: 6: 6: 20C: Ilford HP5

Learn More

Rodinal 1+25 vs 1+50 – Azriel Knight

Rodinal, it’s old as dirt, but people still use it. This awesome little one shot developer has been around since the 1890s and still considered a top choice for black and white photography because it is super easy to use. To develop 43 rolls with the same at 1+50 is 9 hours and 19 minutes, but you’ll still have half the bottle left

Learn More

My approach to Rodinal semi-stand film development - EMULSIVE

This means I'm sometimes using a 1+50 dilution, which with rodinal is enough for a standard development with minute by minute agitations! I'll also add half an hour to the time, and move the point at which I agitate to the new halfway point. For HP5 PLUS at 1600, 18-ish-ml Rodinal, agitation for the first minute, and the four rotations

Learn More

Rodinal 1:25 and 1:50 questions

Apr 19,  · I've never shot HP5 myself, but in my experience, going from 1+50 Rodinal for 12 minutes in Tri-X rated at EI 320, versus 1+25 Rodinal for 5 minutes, 45 seconds (again rated at EI 320), while keeping consistent temperature and agitation yields very different things. The 1+25 developed film is much grainier and accutance was stronger.

Learn More

Rodinal & 35mm Tri-X and HP5+ - Photo.net Photography Forums

I develop 35mm Tri-X in Rodinal at 1:50 for 12 minutes for normal prints. If I want the results to be a little more contrasty or more grainy I used the 1:25 dilution for about 7 minutes. It is my understanding that lower dilutions (more Rodinal to water) yield more grain. I use the 1:50 dilution for the same time with Tri-X in 120 format.

Learn More

How to Make HP5 Looks its Best — Pushed, Pulled, and at Box

Ilford HP5 is a medium-speed black and white film with a rich grain structure and an incredible tonal range. HP5 shows moderate contrast when compared to Kodak Tri-X, making it a better overall film when pushing to higher ISOs. It’s also easy to print and scan, making it one of the best films currently on the market.

Learn More

Anyone else like HP5 souped in Rodinal? : r/Darkroom - Reddit

Rodinal is my developer of choice for nearly all the B&W stocks I shoot. Film Illford HP5 400, 50 mm lens on a Canon AE-1.

Learn More

Rodinal stand development with 1+50?

Mar 02,  · I use my 2-reel Paterson tank and fill it with 6ml Rodinal at 600ml water. Works great. Two inversions at 45 minute mark with a total time of 90 minutes. But I'd like to develop

Learn More

Film developing with Rodinal – developing times, dilution

Mar 31,  · In practice, the dilution 1+50 is used most frequently. It is very convenient because it gives more possibilities to control the entire development process and helps it easier to get

Learn More

Film developing with Rodinal - developing times, dilution, pull & push

Rodinal dilutions Recommended dilutions for Rodinal are 1+25 and 1+50. In practice, the dilution 1+50 is used most frequently. It is very convenient because it gives more possibilities to control the entire development process and helps it easier to get stable results.

Learn More

Recipe Rodinal - gen.omeopatia.genova.it

Search: Rodinal Recipe. The price for ready made Rodinal in $13 I've been reluctant because of all the problems I've read about the full stand method smith water heater temperature sensor, Absolute temperature, also called thermodynamic temperature, is the temperature of an object on a scale where 0 is taken as absolute zero The recipes will be updated soon to include standardized weights and

Learn More

Test accoppiata HP5 - Rodinal 1+25

il test pellicola-rivelatore con Ilford HP5 e Adox Rodinal 1+25. essere quella di passare alla diluizione 1+50 per tutto il test, 

Learn More

Will Hughes on Twitter: "HP5 in Rodinal gets a bad rep - Twitter

HP5 in Rodinal gets a bad rep - this was pushed to 1600 too, and the grain isn't too crazy? Brighton Pier, couple weeks back. At box and 1:50 it is good for 

Learn More

Film Development Chart | 68 °F and agitation 30 Seconds

Development time for 120 Ilford HP5 Plus at 400|27° in ADOX Adonal|Rodinal at 1+25 and 20 °C | 68 °F.

Learn More

Leave A Reply

Reply