UL U415 System B Shaft Wall, Steel Stud (Non-Load-Bearing) Stc 37 Fire Rating 2 Hour System Thickness 3-3/4" PDF (276.2 KB PDF) REVIT (1.99 MB RVT) CAD (66.60 KB DWG) Assembly Details Gypsum Board 1" thick Thick Gypsum Liner Panel (UL Type SLX) Steel Studs 2-1/2" thick CH Studs, 20ga. MSG., Spaced 24" O.C. Gypsum Board

Learn More

PDF Shaft Wall - ConstructionPDF

The assemblies listed below are a small sample of the UL Designs in which USG shaft wall systems can be used. For more details on fi re-rated assemblies, see USG literature SA926, Shaft Wall Systems. SSA926S_08.indd 3A926S_08.indd 3 99/13/07 1:33:52 PM/13/07 1:33:52 PM

Learn More

What You Should Know About Cavity Shaftwalls

Can horizontal shaftwall assemblies be used for a rated corridor ceiling? National Gypsum's UL Cavity Shaftwall Systems (1-4 hour) 

Learn More

UL U415 System A - Wall Assembly - Knauf Insulation

UL U415 System A. Shaft Wall, Steel Stud (Non-Load-Bearing) · Stc. 0 · Fire Rating. 1 Hour · System Thickness. 4-5/8".

Learn More

Assemblies Archive - Georgia-Pacific Building Products

Hourly Rating: 2-hour. Fire Test Reference: GA WP 1955. Area Separation Wall. Two layers 1” (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner 

Learn More

UL Wall Assemblies with STC and Fire Ratings - Knauf Insulation

Find resources and details for UL rated wall systems with the required STC and fire ratings for your project. UL Wall Assemblies BIM - Revit Library Transparency Catalog > NAIMA 3E

Learn More

UL Wall Assemblies, Fire Rated Wall Designs - USG

USG's range of resources on UL wall assemblies can help with the planning and Shaft Wall - Steel Stud (Non-Load-Bearing). Fire Rating. 1 hours.

Learn More

What You Should Know About Cavity Shaftwalls - National Gypsum

11/1 · Can horizontal shaftwall assemblies be used for a rated corridor ceiling? Yes, National Gypsum has several options for rated horizontal systems: 2-hour rated UL Design G586 or 1- and 2-hour horizontal shaftwall assemblies per UL Evaluation Report: ER R3501-02 (Section 6.3.1). These are typical horizontal assemblies used in a fire-rated corridor.

Learn More

2-hr. Fire Rated Wall Construction Overview - Henrico County

The two layers of 1″ gypsum shaft liner provides the 2 hour rating, and Many 1-hr. rated wall assemblies listed in UL will allow.

Learn More

National Gypsum Company Fire-rated Assembly in ... - Macopa

UL Design. Head of Wall Firestop System. Page. Detail No. Title. SW Series - Shaftwall Assemblies 09 21 16.23. SW 101. 1 Hour Shaftwall Partition.

Learn More

One Hour Fire Rated Assemblies - Structural building components

Answer: Generally, there are two types of 1-hour wood truss assemblies: the first is one layer GWB with metal furring strips or resilient channel, and the second is two layers GWB board. An

Learn More

UL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly - BuildSite

UL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly Documents (1) Add to Package Installation Instructions - UL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly (454 Kb, 11pg) System

Learn More

Design Details Details Page - Shaft Wall 1-Hr. AER-09038 - USG

Wall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details; UL Type Designations; Frequently Asked Questions; Acoustical Ceilings Performance Substrate; Sealant Fire Tests; Material Estimators Material Estimators. Shaft Wall 1-Hr. AER-09038. More; Need Help?

Learn More

CT Shaft Wall Stud System Catalog_070622.indd - CEMCO

and gypsum Shaftliner manufacturers are approved in several UL fire- rated assemblies for both 1 and 2-hour ratings . ASTM & Code Standards. • ICC-ESR 4934.

Learn More

AG Design Library - American Gypsum

Second, choose the type of design you are seeking (example – Walls/Partitions (steel framed), Floor/Ceiling (wood framed), etc.) Or search by the assembly number (UL design, or Gypsum Association file number) Then click on the Search button, and your results will be displayed below. 1-800-545-6302 ext. 5607 [email protected]

Learn More

Shaft Wall Solutions for Wood-Frame Buildings: Codes & Detailing - Civil

Several options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC Table 721.1 (2), Item 14-1.3 UL U332 1-Hour Double Wall UL U341 2-Hour Single wall UL U301 UL U334 IBC Table 721.1 (2) Item Number 14-1.5

Learn More

Fire-Rated Wall Assemblies - LP Building Solutions

Fire-Rated Wall Assemblies. LP® FlameBlock® Fire-Rated OSB Sheathing is a component of the following 1-Hour Exterior Wall Assembly - UL Design No. U348 

Learn More

Looking For Better Rated Horizontal Membrane Assemblies? - National Gypsum

6/23 · UL design G586 can span 8’-0” from wall to wall or indefinitely when used in conjunction with the hanger assembly. For 1-hour assemblies, National Gypsum developed UL design I504, which is a 1-hour horizontal assembly that consists of 3-5/8” steel studs 16” o.c. with three layers of 5/8” Type X gypsum board applied to the underside of the framing.

Learn More

UL Wall Assemblies, Fire Rated Wall Designs | USG

Wall Assemblies USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and

Learn More

Shaftwall - Georgia-Pacific Building Products

Shaftwall. One layer 1″ x 24″ (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panel inserted between 2-1/2″ floor and ceiling runners of 2-1/2″ steel C-T, C-H studs. Opposite side:

Learn More

Shaft Wall Solutions for Wood-Frame Buildings: Codes

Several options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC

Learn More

UL Wall Assemblies, Fire Rated Wall Designs | USG - CGC Inc

USG's range of resources on UL wall assemblies can help with the planning and estimation of Chase Wall - Wood Stud (Load-Bearing). Fire Rating. 1 hours.

Learn More

Ul u529 shaft wall - zsi.szaffer.pl

A 2-hour fire-resistive, non-load bearing non-combustible partition designed to enclose shaftwalls, containing elevators, ducts, piping, air shafts and similar construction applications. System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T studs and faced on one side with two layers of 1/2" Type C or 5/8" Type X gypsum board.

Learn More

Shaft Wall - Construction

Fire-Rated Assemblies 3 USG Shaft Wall Systems 09 20 00/USG BuyLine 2425 1 Hour Fire-rated Construction Non-loadbearing Acoustical Performance Construction Detail Description Test Number STC Test Number wt. 8 † 5/8 SHEETROCK® brand FIRECODE® Core gypsum UL

Learn More

UL U415 System G - Wall Assembly - Knauf Insulation North America

Assembly Details Gypsum Board 1" [25.4 mm] Sheetrock ® Gypsum Liner Panels (UL Type SLX) Steel Studs 2-1/2" [64 mm] CH studs, 20 ga. (0.033"), 24" [610 mm] O.C. Insulation 2-1/2" [64 mm] Knauf EcoBatt Insulation Gypsum Board 3 layers of 5/8" [15.9 mm] Sheetrock ® EcoSmart Gypsum Panel (UL Type ULIX ™) Notes View assembly information on UL Website.

Learn More

Fire Resistance - International Code Council

UL 263. ASTM. E119. Standards Used to Evaluate Assemblies Yes, this is a shaft wall. The rating – 1 Hour. ➢ The load capacity – Bearing. Wall 

Learn More

UL Wall Assemblies with STC and Fire Ratings

UL Wall Assemblies. Find and download resources for STC rated wall assemblies for your construction project. Revit, CAD, and construction details for fire 

Learn More

GlasRoc® Shaftliner and M2Tech® Shaftliner - CertainTeed

Attach 2" (51 mm) wide C-Track to slab at bottom of wall using suitable fasteners at a maximum of 24" (610 mm) o.c. Allow a 3/4" (19 mm) space from wood or steel stud framing on each side of the firewall. 2. Install vertical C-Track at the beginning of the wall and support as needed. 3.

Learn More

PDF Cgc Shaft Wall Systems - UsgPDF

CGC Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.

Learn More

Horizontal Shaftwall Duct and Ceiling Assemblies

TWO HOUR HORIZONTAL DUCT PROTECTION. WHI 694-0300.1. 09260GG. Scale: 2" = 1'-0". FLEXIBLE SEALANT. Horizontal Shaftwall Duct and Ceiling Assemblies.

Learn More

Shaft Wall Solutions For Wood-Frame Buildings - WoodWorks

were to fail at 1 hour, the wall above could not continue UL U334. FIGURE 5: Shaftliner Wall Assembly with Wood Wall Each Side. FIGURE 6:.

Learn More