CVU Series Metro Fluid Power specializes in the supply of current and obsolete Vickers Pumps, Vickers Motors, and Vickers Valves. Call today for an on the phone quote. Complete units, parts, repair, and repair information. Model Codes Vickers CVU 16 C025 B29 10 Eaton 479523 REQUEST QUOTE Vickers CVU 16 C3 B29 W 250 30
Learn MoreModel code: DG4V37CMUH760. Make: Eaton/vickers".This tender belongs to Directional control valves category. Refer below for a pictorial view and a tabular
Learn MoreEATON Vickers Solenoid Operated Directional Valves Catalog V-VLDI-MC008-E September 2008. Model Codes. DG4V3-70. Directional. Control Valve.
Learn MoreServo valves: Eaton Vickers two-stage, four-way, flapper nozzle servo valves provide closed loop control with exact positional accuracy, repeatable velocity, and predictable force and torque regulation. Please contact us if you cannot see the Eaton Vickers hydraulic valves that you need listed below – we’ll still be able to help!
Learn MorePart Number & Model Code Matches. MENU Danfoss Powersource® Powering Business Worldwide. Products . Industrial Valve. Knife. Lock Washer. Mcd - Al. Mcd - Al2. Mcd - Classics. Mcd - Fe. Medium Duty Cc. Metric Tube Fittings. Motor. Vickers F3DG4V4018BMU1H510 Valve Denison (A) 3D0234112030200B1GOQ327
Learn MoreVickers DG5S8 Metro Fluid Power specializes in the supply of current and obsolete Vickers Pumps, Vickers Motors, and Vickers Valves. Call today for an on the phone quote. Complete units, parts, repair, and repair information. Model Codes Vickers DG5S-8-0A-1-E-M-FTWL-B5-30 Eaton 02-144158 REQUEST QUOTE Vickers DG5S-8-0A-2-E-M-FPA5WL-B5-30 Eaton 02
Learn Moresize 5 main stage valves are standard Vickers units com-plete with their individual nameplates including model code and symbols. The main stage carries the model code of the 2-stage valve and the functional symbol of the main stage spool. Referring to the examples, nameplates are located as follows: 1. On main stage (DG3V-5/DG5V-5) 2. On cover
Learn MoreModel Code Special Seals (Omit if not required) F3 - Seals for fire resistant fluids F6 - Seals for water glycol Directional Control Valve DG5V - Subplate mounting; solenoid controlled; pilot operated. Pressure rating 350 bar (5000 psi) for P, A, & B ports. Valve Size 10 - Valve size CETOP 10, NFPA D10 Pilot Valve Type H - CETOP 3 mounting
Learn MoreVickers® Directional Controls Directional Control Valves Wet Armature Solenoid Operated DG4S*-01, 60 design. 2 Table of Contents Model Code $ # : ; ˝ $ $$ $ 9ˆ˘5%˜ ˘ ˆ + %˜0 ˆ ˆ " #
Learn Morethe valve on a manifold or subplate containing the interface. Valves are available with AC or DC solenoid(s). Electrical connections to the valve are made in an electrical wiring terminal box or by various plug-in devices. A ground terminal is provided. Model Code Two & Four-way Directional Valves Spool/Spring arrangement A - Spring offset
Learn MoreVickers pressure control screw-in cartridge vale. Its purpose to to provide a quick, convenient reference tool when choosing Vickers cartridge valves or designing a system using these components. Vickers offers a full range of direct and pilot operated relief, reducing, sequence and unloading valves. In general, the direct operated products are
Learn MoreVickers Solenoid Coil Replacement - Find a Replacement Model Here, vickers solenoid valve coil replacement, We are a professional solenoid valve coil manufacturer and can provide you with high-performance solenoid valve coils. The solenoid valve coils we produce are comparable in quality to Vickers coils, but our price is much lower than it.
Learn MoreModel code. 1. Model series. D. Directional valve. G. Subplate/manifold mounted. 4. Solenoid operated. V. Pressure rating 250 bar (3600 psi).
Learn MoreCETOP 3 Size Soft Shift. Directional Control Valves. Vickers® DG4V-3(S) Model Code allow for fine tuning of valve shift time to each application.
Learn MoreModel number, assembly number, coil designator, tank pressure, and graphic symbol must be imprinted by person performing conversion. Spool accessory kits. These
Learn MoreModel Code 05 Operating Data 07 Performance Data 09 Installation Dimensions 12 DG4V-3-*A(L)-(V)M-S6-U-**-60 14 with Vickers® SystemStak valves and subplates. DG4V-3 and DG4V-3S High and standard performance models: • Up to 80 l/min (21
Learn MoreBuy Vickers (Danfoss) DG4V-3S-2C-M-U-B5-60-EN21 02-144363 Directional Control Valve - Solenoid Actuation, 4-Way, D03 Valve, 10.5 gpm Max Flow, 110 V ac (50 Hz) / 120 V ac (60 Hz) Coil at Motion Industries. Keeping Your Industry In Motion Since 1972!
Learn More4 DG3V-8 Remote Pilot Operated Directional Valves Model Code 1 23 87 9 10 Special Seals (Omit if not required.) F3 - Seals for fire resistant fluids. F6 - Seals for water glycol. Directional
Learn MoreMODEL KNOB CORE TUBE S/A 508113 508113 694274 694272 02-113349 Screw(4 Req'd) NOTE Refer to other end of valve for common part numbers. DG4V-3(S)-*C-FJ/FW-60 Spring centered DIN Coil (See Table) 508111 508124 890246 694323 Double solenoid valves, spring centered Transient condition only. 890332 Gasket 890330 Strap 36212 Screw (2 Req
Learn MoreETN VICKERS hydraulic valve MODEL CODE DG4V-3-2C-M-U-D6-60 DG4V32CMUD660 coil D-507834 220V 50 240V 60 · 1. WORLDWIDE SHIPPING . · 2. Orders processed timely
Learn MoreSequence 1 seal type No preference 1 · Sequence 2 valve type (DG4V) SOL. · Sequence 3 interface (3) ISO/DIN 4401-AB-03, SIZE 3 INTERFACE -3 3 · Sequence 4
Learn MoreFlow Rating Model Code 6 DG17S-8 Flow Ratings AB PT AB PT AB PT 1 2 3 Spring Centered -C- Spring Offset -A- No-Spring Detented -N- All Spools 0, 2, 6 & 33 All Spools Standard Spool Types Center Position & Spool Type Description Center Position Recommended Flow Capacity at 210 bar (3000 psi) l/min (USgpm) DG17S-8-0C-10 AB PT
Learn MorePA3 - (pa3) 3-pin connector (requires w or lw in model code) PA5 - (pa5) 5-pin connector (requires w or lw in model code) PB - (pb) inst-plug (male plug & receptacle) _ - omit if not required, Sequence 4, valve type, DG4S - (dg4s) solenoid operated directional control valve with 3600 psi max, Sequence 5, flow direction, no preference,
Learn MoreElectrical connections to the valve are made in an electrical wiring terminal box or by various plug-in devices. A ground terminal is provided. Model Code.
Learn MoreVickers Pumps are capable of pushing large amounts of oil through cylinders. Their unique design allows for easy repair and interchangeability between pumps in the event that upgrades are necessary. Designed to provide low-to-medium hydraulic pressure, the Vickers V10/V20 pumps feature integral valve options that have reduced the size and
Learn MoreEATON Vickers Proportional Two-Stage Directional Valves KBFDG5V-5/7/8/10 V-VLDI-MC003-E2 February 2010. Model Code. Valve type. K – Proportional valve.
Learn MoreVickers Directional Controls Speed control orifice plug, optional. See model code description A.1 Model DG4V-5, 20 Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage General Description Max. pressure 315 bar (4500 psi). . . . . . Max. flow rates Up to 120 L/min. . . . . . .
Learn MoreThe parts and installation drawings listed in Table 1 are available from any Vickers sales engineering office C. Model Codes Variations within each basic model series are covered in the model code. See Table 2. Each unit has a model code marked on the main stage nameplate.
Learn MoreSeries DGMFN-H8 Model Code F3 DGMFN H8 * A2W-B2W 10 1 Seal Options F3 – Fluorocarbon seals, for Phosphate Ester (class L - HFD) Blank – Nitrile, for Mineral oil Anti-wear hydraulic oil (class op in bar L - HM), Invert emul- ting in sion
Learn MoreModel Code 05 Operating Data 07 Performance Data 09 Installation Dimensions 12 DG4V-3-*A(L)-(V)M-S6-U-**-60 14 with Vickers® SystemStak valves and subplates. DG4V-3 and
Learn MoreVickers ® Directional Controls Directional Control Valves Wet Armature Solenoid Operated DG4S*-01, 60 design Model Code $ # : ; ˝ $ $$ $ 9ˆ˘5%˜ ˘ ˆ + %˜0 ˆ ˆ " # ˚ ˜% ˘ ˙ 04 ,3 ˆ ˆ 7,8 ˘ ˇˇ ˚ ˆ ˘ˆ2 "˚ ˇ˘ > $ ˝ ),%!˘ %ˆ ˚ˆ
Learn More
Leave A Reply