size and promoting decay, leading to unpleasant odor and unsanitary conditions. Under these conditions, pipes can readily become clogged GREASE INTERCEPTORS ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA 16502 PHONE 814/455-0921 FAX: 814/454-7929 WEBSITE: www.zurn.com
Learn More67227 ENGINEERING SPECIFICATION: ZURN Z1172 Large capacity Acid Resistant Coated interior and exterior fabricated steel grease interceptor, rated at ____
Learn MoreZurn toilets include wall mounted toilet, floor mounted toilet, two-piece gravity toilet, and two-piece pressure assist toilet.. CROSS REFERENCE GUIDE Keeney Kohler Eljer AM. Standard Crane McGuire Watts Dearborn Zurn 5303PC K-8998 804-1180 4401.014 8-5260 8872 518173 507-1 Z8700B-PC 5303PC866CR - - - - 8872CBECO 518173B 507BN-1 Cast Body P-Trap 5303PC 1
Learn MoreGrease Interceptors. Design & Operation. Material & Characteristics. Sizing. Pipe Connection. Commonly Specified Options. Installation Considerations.
Learn MoreSizing a Grease Trap or Interceptor · You'll need to measure the fixture's length, width, and height to determine the fixture's capacity in cubic inches (LxWxH).
Learn MoreGrease Interceptor: 4 in Pipe Dia., 100 gpm Flow Rate, 180 lb Capacity, Polyethylene ; Overall Height 54 in ; Overall Width 31 in ; Overall Depth 66 in ; Max. Temp.
Learn MoreGrease Trap Sizing Calculator ; Compartment Sink # 2 - Totals ; Maximum Discharge (2 Sinks Combined) ; Drainage Load - 75% of Maximum Discharge
Learn MoreCalculating Grease Trap Requirements For Dish Machines · 10-15 Gallon Capacity Dish Machine Tank: 15 Pound Grease Trap · 20-30 Gallon Capacity Dish Machine Tank:
Learn MoreGravity Grease Interceptor Sizing By Pipe Size (Using City of Houston Plum GREASE INTERCEPTORS ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE
Learn MoreCommercial grease traps are sized according to the rate of incoming flow, in gallons per minute (GPM). Associated with this incoming flow rate is the trap's capacity. This rated capacity, in pounds, is listed at twice the flow rate. For example, a 10 GPM trap has a rated capacity of 20 pounds.
Learn MoreFormula Explanations Grease Trap Sizing (Hydro Mechanical) 2 or 3 Compartment sink Cubic Capacity = width x length x depth (in inches) Volume in Gallons = Cubic Capacity / 231 1 US Gallon = 231 cubic inches (volume) Remember: Hydro Mechanical Interceptors are Measured By FLOW (GPM) Grease Interceptor Sizing (Gravity)
Learn MoreZ1173-RD – Sizes 200-800. GREASE INTERCEPTORS. ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA
Learn MoreZurn offers a full line of Oil and Solids Interceptors designed specifically for the auto industry with sizes up to 10,000 gallons. Traps & Primers. Stainless Drains. Light Commercial. Trench Drain Systems. Acid Neutralization. Liquid Volume Sizing (U.S. G/L) 50 (189)
Learn MoreCalled Zurn and they suggested interceptor 2700-50 seems awfully big for an under the sink Grease Trap with 4" in 4" out.
Learn MoreTable 4 on the next page (“HGI Sizing Chart”) is used to determine the size of HGI needed, if that is the type of grease interceptor being installed. In Example 1, based on 29 DFUs a 75 gallon per minute (gpm) unit would be required. In Example 2, a 50 gpm unit would be required.
Learn More1/17 · For restaurants, the sizing formula is: Formula 2. Grease Interceptor Liquid Capacity, U.S. EPA Method. 6 Where D = Number of seats in dining area GL = Gallons of wastewater per meal, normally 5 gallons ST = Storage capacity factor – minimum of 1.7, on-site disposal, 2.5 HR = Number of hours open LF = Loading factor 1.25 – interstate freeways
Learn MoreThese Zurn grease traps are identified by their pound (#)and gallon per minute (gpm) capacity. In order to find the right grease trap for your given application, you should know the size of the sinks which the grease trap will be used for. We also carry several solids interceptors. These products are not grease traps, but instead are made to catch small solid objects. Grease traps may be
Learn MoreHydromechanical Grease Interceptor (HGI) Sizing Chart DFUs (1) HGI Flow (gpm) 8 25 13 35 20 50 35 75 172 100 216 150 342 200 428 250 576 350 720 500 (1) The maximum allowable number of DFUs that can be connected to the grease interceptor. The information in the above tables is from section 702.0 and tables 7-5, 10-2 and 10-3 of the
Learn MoreSizing - PDI Method Using Sink Volumes. Installation of Grease Interceptors. Maintenance of Grease Inteceptors. Product Information. Z1174 Installation Instructions. Z1192 Grease Recovery Appliance. Operations and Variations. Chemical Resistance Information. Materials and Finishes.
Learn MoreA correctly sized grease interceptor reduces maintenance costs for restaurants as well as the chance of a messy and costly clog/backup. Right sizing is critical in choosing the correct grease interceptor, and we’ve got it down to a science. It’s called Grease Production Sizing Method (GPSM). GREASE PRODUCTION SIZING METHOD (GPSM)
Learn MoreLearn the basic formula for sizing a grease trap or grease intercepotr.
Learn MoreGREASE INTERCEPTORS ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA 16502 PHONE 814/455-0921 FAX: 814/454-7929 WEBSITE: www.zurn.com Page 12 Z1171-TD and Z1173-TD Grease Interceptor With Top Draw-off To assist in the maintenance and cleaning process of grease inter-
Learn MoreThe purpose of this document is to set forth the requirements for the sizing and installation of grease removal devices in.
Learn MoreUnder the BS EN 1825 calculation, we can determine the correct size by two methods: OPTION 1 - Type of Kitchen This looks at the type of operation, such as restaurant, school, hospital etc and requires the input of average meals per day with the kitchen operational hours per day. OPTION 2 - Type of Equipment
Learn MoreZURN GREASE INTERCEPTOR SIZE PER PDI METHOD (TWO-MIN. SINK DRAIN TIME) START NOTES: 1. PREFERRED GREASE INTERCEPTOR SIZE IS BASED ON ONE MINUTE SINK DRAIN TIME. 2. ALTERNATIVELY, A SLOWER TWO-MINUTE SINK DRAIN TIME MAY BE USED IF ACCEPTABLE TO LOCAL CODES. THIS WOULD RESULT IN A PHYSICALLY
Learn MoreZurn manufactures the largest breadth of engineered water solutions in the industry, including a wide spectrum of sustainable plum products such as Light Duty Commercial Grease Traps, Heavy Duty Commercial Acid Resistant Grease Interceptors , Oil and Sediment Interceptors , Solids Interceptors and Low Profile Grease Traps.
Learn MoreGREASE INTERCEPTORS ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA 16502 PHONE 814/455-0921 FAX: 814/454-7929 WEBSITE: www.zurn.com Page 4 Four factors are critical to the proper operation of a grease interceptor: Design, Sizing, Proper Installation, and Maintenance.
Learn MoreGrease Interceptors from Zurn's are CSA and PDI Certified. Our Grease, Oil and Solid Interceptors are high performing and come in different variants, the right fit for All of Your Separation Needs Liquid Volume Sizing (U.S. G/L) 50 (189) Grease Interceptor are manufactured with patented distributed flow pattern and corrosion resistant
Learn MoreThe Plum and Drainage Institute list of grease interceptors certified to Grease Interceptors with Sensing and Alarm Devices Zurn Green Turtle.
Learn MorePDI Size Grease Interceptor 1 1/4 1 7.5 10 1 1/2 2 15 15 2322.525 2 1/2 4 30 35 3537.550 464550 Since the possibility of all the fixtures are used and drained simultaneously is very low, using above sizing method can potentially result in an enormous flow The
Learn Morecannot be specified when the aluminum cover is used. –BB Timer Battery Backup(For Z1174) –C30 Cable Length of 30 Feet For Digital Display(For Z1192) –C45 Cable Length of 45 Feet
Learn More
Leave A Reply